إعلان فيروس كورونا: نحن دائما بجانبك!اقرأ المزيد للحصول على التحديثات والموارد التي قد تحتاجها




MINIMED™
670G System
The world's first self-adjusting
insulin pump system 1 2 3
Some user interaction is required
Believe in better control




"My HbA1c dropped from 7,6% to 6,9% in less than 3 months."
MiniMed™ 670G System user




How it works
Simplify glucose levels adjustment
MINIMED™ 670G SYSTEM COMPONENTS




CONTOUR® NEXT LINK 2.4 Blood Glucose Meter
The only meter to link wirelessly to the MiniMed™ 670G insulin pump for highly accurate sensor calibration7


MiniMed™ Mio™
Infusion Set
Whether you are new to insulin pump therapy or an experienced pumper, Medtronic offers a range of infusion sets to suit your individual needs, preference and lifestyle.


CareLink™ Software
Upload to CareLink™ software to gain vital insights into your diabetes therapy and remotely share your information with your healthcare professional for a more informed discussion when you are next in clinic.
CONTOUR® NEXT LINK 2.4 Blood Glucose Meter
The only meter to link wirelessly to the MiniMed™ 670G insulin pump for highly accurate sensor calibration7
MiniMed™ Mio™
Infusion Set
Whether you are new to insulin pump therapy or an experienced pumper, Medtronic offers a range of infusion sets to suit your individual needs, preference and lifestyle.
CareLink™ Software
Upload to CareLink™ software to gain vital insights into your diabetes therapy and remotely share your information with your healthcare professional for a more informed discussion when you are next in clinic.
previous therapy
100% of healthcare providers whose patients used the MiniMed™ 670G system reported that it was better than any previous therapy.7
glucose control
96% of previous multiple daily injection (MDI) users self reported that the MiniMed™ 670G system met or exceeded their expectations for improved blood glucose control.6
to manage diabetes
75% users reported the MiniMed™ 670G system met or exceeded their expectations for less day-to-day effort managing diabetes.4
89% of users reported that the ease of learning how to use the MiniMedTM 670G system was good or excellent.4







إذا رغبت في معرفة المزيد حول نظام ميني ميد™، اترك لنا بياناتك وسوف نتواصل معك.



Water Resistance | Waterproof pump, protected against the effects of being underwater to a depth of up to 12 feet (3.6 meters) for up to 24 hours. |
Sizing | The pump dimensions in inches are approximately 2.1 width x 3.78 length x 0.96 depth. The weight of the pump is approximately 96 g. |
Environmental Conditions | The MiniMed 670G insulin pump system is designed to withstand most conditions encountered in your daily life. Pump storage temperature range is from -20 °C to 50 °C. Air pressure range is from 700 hPa to 1060 hPa (10.2 psi to 15.4 psi). |
Pump Memory | At any time the user can review 90 days of pump history |
Compatible Infusion Sets | Medtronic Diabetes provides a variety of infusion sets to fit your needs. |
Guardian Link 3 Transmitter | Used with your pump for Continuous Glucose Monitoring (CGM). A device that connects to a glucose sensor. The transmitter collects data measured by the sensor and wirelessly sends this data to monitoring devices. |
Bolus Speed Options | Standard: 1.5 units/minute Quick: 15 units/minute |
Bolus Programming Increments | 0.025 units 0.05 units 0.1 units |
Altitude Range | Pump operating range is from 10.2 psiA (70.33 kPa) to 15.4 psiA (106.18 kPa) Storage range is from 7.2 psiA (49.64 kPa) to 15.4 psiA (106.18 kPa) |
Backlight | Type LED (Light-emitting Diode) Time out 15 seconds (default), 30 seconds, one minute, three minutes Time out when battery is low 15 seconds (default), 30 seconds |
Basal Delivery Rate Range | 0 to 35 units per hour or the Max Basal Rate amount, whichever is lower. |
Guardian Sensor 3 | Used with your pump for CGM. The sensor is a small part of the continuous glucose monitoring system that you insert just below your skin to measure glucose levels in your interstitial fluid. |
CareLink™ USB | Used to upload system data to the diabetes management software using a USB port on your computer. |
One-Press Serter | The serter is used as an aid for inserting the sensor. It is indicated for single-patient use and is not intended for multiple patient use. |
Battery & Power | The pump requires one new AA (1.5 V) battery. For best results, use a new AA lithium (FR6) battery. The pump also accepts an AA alkaline (LR6) or a fully charged AA NiMH (HR6) nickel-metal hydride rechargeable battery. |
Reservoir | Medtronic reservoir MMT-332A, 3.0 ml (300-unit) |
CONTOUR® NEXT LINK 2.4 Glucose Meter | The MiniMed 670G system comes with a compatible meter. It wirelessly connects to your pump, allowing you to send BG meter readings to your pump. |
See the device manual for detailed information regarding the instructions for use, indications, contraindications, warnings, precautions, and potential adverse events. For further information, contact your local Medtronic representative.
- Iturralde E, et all. The Diabetes Educator. 2017; 43(2):223 – 232
- Bergenstal, R. M. et al. Jama. 2016; 316 (16): 1407 – 1408
- Garg SK et al. Diabetes Technol Ther. 2017 Mar;19(3):155-163
- Data on file. MiniMed 670G user experience survey, period Jun 2017 - Jan 2018, n=13.571
- Data on file. Survey of customer training phase patients.
- Gopalakrishnan S, et al. Diabetes Technol Ther. 2018 Feb;20 (S1): ATTD8-0240
- Chen J, et al. Diabetes Technology Meeting 2017. Journal of Diabetes Science and Technology, vol. 12, 2: pp. 426-532 (A10)